OVERVIEW

This Liebert GXT3 10kVA unit offers a flexible solution for protecting rack-mount equipment, including VoIP and PoE. 

Especially designed for use with the new generation of high power switches, this compact UPS system packs 10kVA (9kW) of power into a 6U rack/tower package with flexible output voltage and bundled output distribution and maintenance bypass.
 
The UPS includes built-in user-replaceable batteries for up to 3 minutes of runtime at full load.

 

 

24 Months Warranty
SPECIFICATIONS

 
Model Number    GXT3-10000RT230    
Rating(VA/W)    10000VA/9000W    
Physical Dimensions        
Unit: WxDxH(mm)    430x577x261    
Shipping: WxDxH(mm)    515x717x570    
Weight        
Unit (kg)    
80

Shipping (kg)    
82

Input AC Parameters        
Operating Frequency    50 or 60Hz Nominal (factory Default=50)    
Factory Default    230VAC    
User Configurable    220/230/240VAC    
Operating Voltage Range (w/o battery operation)    176-280VAC    
Maximum Allowable    280VAC    
Input Frequency (w/o battery operation)    40 to 70Hz    
Input Power Connection    PD2-CE10HDWRMBS Standard    
Output AC Parameters        
Factory Default    230VAC    
Output Connections    PD2-CE10HDWRMBS Standard    
Frequency    50 or 60Hz Nominal    
Waveform    Sinewave    
Main Mode Overload    >200% for 5 cycles; 151 to 200% for 1 seconds; 1331 to 150% 10 seconds; 105 to 130% 1 minute    
Battery Parameters        
Type    Valve-regulated, non-spillable, lead acid    
Quantity    20 x 12V    
Recharge Time (internal batteries)    3 hrs to 90% capacity after full discharge into 100% load    
Bypass Protection Limits        
Disable Bypass Operation    If input voltage exceeds ± 15% of the nominal voltage    
Re-Enable Bypass Operation    If input voltage returns to within ± 10% of the nominal voltage    
Disable Bypass Operation    When the input frquency prevents synchronous operation    
Environmental        
Operating Temperature (°C)    0 to 40    
Storage Temperature (°C)    -15 to 50    
Relative Humidity    0 to 95%; non-condensing    
Operating Elevation    Up to 1000m at 30°C without derating    
Audible Noise    < 55dBA at 1 meter from the rear; < 50 dBA at 1 meter from the front or sides    
Agency Approvals        
Safety    IEC62040-1:2008 version    
EMI/EMC    IEC/EN/AS 62040-2 2nd Ed (Cat 2-Table 6)    
ESD    EN61000-4-2,Level 4, Criteria A    
Radiated Susceptibiltiy    EN61000-4-3,Level 3, Criteria A    
Electrical Fast Transient    EN61000-4-4,Level 4, Criteria A    
Surge Immunity    EN61000-4-5,Level 3, Criteria A    
Transportation    ISTA Procedure 1A